Component Mass Balance - Manifold ExampleFigure 271: Component Balance - Manifold example

Mass and component balance is performed on the manifold above with components A, B, C. The measured values and the results are listed in the table below. Notice that a manifold preserves the component fractions from the input to the output flows.

Component Mass Balance - Manifold Example

FlowMeasurementToleranceReconciled Value
F11000 ton20 ton
A0.7.0140.6170
B0.30.0060.2847
C0.10.0020.0983
P1450 ton9 ton
A\<Not Measured>-0.6170
B\<Not Measured>-0.2847
C\<Not Measured>-0.0983
P2556 ton11.12 ton
A\<Not Measured>-0.6170
B\<Not Measured>-0.2847
C\<Not Measured>-0.0983